Diagnostic Services
When a channel reads wrong or a machine starts to change, you need an answer you can act on — not more raw data. Our diagnostic team combines field measurements with engineering judgement to tell you what is happening, what it means, and what to do about it, so problems are caught early and shutdowns stay planned.
Ready to start?
Find the fault before the machine finds it for you
Vibration carries a signature of everything happening inside a machine. We read that signature — spectra, waveforms, orbit and Bode plots — and tell you exactly what is wrong, which component is affected, and how long you realistically have before it becomes a shutdown.
What you get
- A clear diagnosis, not a data dump — named fault, affected component, severity
- Bearing, imbalance, misalignment and looseness identification
- Run-up and coast-down analysis for rotor and support issues
- A written report with findings, evidence and a recommended course of action

Measurements you can defend
A protection system is only as trustworthy as the numbers feeding it. We calibrate measurement channels end to end — from the sensor at the machine through to the monitor output — so the value shown on the rack is the value actually being measured.
What you get
- Full channel calibration from sensor to monitor output
- Vibration, displacement, temperature and other measurement channels
- Verification against manufacturer specification
- Signed calibration certificates for your records and audits

Proof that your instruments meet spec
Independent verification of sensor measurement characteristics against manufacturer specifications and applicable standards. Useful when equipment changes hands, when an audit is coming, or when you simply need to know whether a suspect channel is telling the truth.
What you get
- Sensitivity and linearity verification across the working range
- Frequency response and phase checks
- Comparison against manufacturer specification
- Documentation suitable for audit and compliance purposes

Know your trips will fire when they matter
A protection system that has never been tested is an assumption, not a safeguard. We verify the whole chain — setpoints, voting logic, relay outputs and shutdown paths — so you know the system will act correctly the one time it has to.
What you get
- Alarm and danger setpoint verification on every channel
- Relay output and voting logic testing
- End-to-end functional test of the shutdown chain
- Full test documentation with results per channel

Ready to Get Started?
Get a free consultation from our engineering team. We will analyse your requirements and propose the optimal monitoring and protection solution.